WHAT IS CQI-9

CQI-9 Special Process: Heat Treat System Assessment, 4th Edition was published in June 2020. We are here to help you achieve compliance with these new standards.

DEFINITION AND PURPOSE

According to the Automotive Industry Action Group (AIAG), CQI-9 4th Edition was developed in collaboration with volunteers from OEMs, Tier 1 suppliers, heat treat suppliers, and calibration companies that service the heat treat industry, the Special Process: Heat Treat System Assessment 4th edition (CQI-9) is a comprehensive audit covering the most common heat treat processes employed by the automotive industry, intended to provide a common approach to a heat treat management system for automotive production and service part organizations.

COMPLIANCE PACKAGES AND OPTIONS

Our experts at Gasbarre have a comprehensive knowledge of CQI-9 Special Process: Heat Treat System Assessment 4th Edition. We will develop and implement a compliance plan for you. Although every situation is unique, we have two main options to get your thermal processes ready for this new revision.

Gasbarre CQI-9 Advanced & Basic Compliance Assistance Packages

NEW REQUIREMENTS: ARE YOU READY? ARE YOU IN COMPLIANCE?

Several key points required by CQI-9 Special Process Heat Treat System Assessment 4th Edition:

MTI Logo
Forging Industry Association Logo
MPIF Member Logo

  • Digital instrumentation required

  • Temperature recording required for each control zone

  • Quarterly calibration of atmosphere controllers

  • Recording instruments are required for temperature controlling devices and protective atmosphere monitoring

  • Continuous temperature recording with an alarm system

  • Continuous atmosphere recording with an alarm system

  • Record cooling water temperature twice per shift, continuously record and sign off twice per shift, or alarm system on temperature recorder

  • For sintering hardening, an alarm system is required for proper fan
    operation and fan speed verification every 8 hours

  • Continuous monitoring of furnace atmosphere required,
    automatically controlled, and documented